Page 55 of 66
©Retrotec Inc. 2012
Appendix A: System Flow Equations for all Devices
The following equation can be used to determine flow, using the variables listed in the table below.
Each fan has a different flow equation, incorporating N and K values related directly to that particular
fan.
where: FP is the fan pressure, and CR is the corrected room pressure
Note: CR can be determined by subtracting bias pressure from room pressure, by using the “Baseline”
feature on the DM-2, or by retrieving corrected pressure from FanTestic.
To determine the fan flow for a particular fan pressure, insert the values for FP, CR, and the N and K
values (based on the type of fan and its Range Plate/Range being used).
The Fan Pressure (FP or "PrB" reading on the DM-2) must be greater than the minimum Fan Pressure,
“MF” in the Table 8, and greater than (PrA*K2)
Table 8. N and K coefficients for all DM-2 supported fans.
Retrotec
1000 / 2000 /
3000 /
3000SR